Leading Healthcare Solutions

FulCare
HVAC

Cleanroom Purification HVAC Unit

Ultra-hygienic cleanroom air-handling unit designed to EN1886, with 2,000–120,000 m³/h airflow, up to 2,500 Pa pressure, anti-cold-bridge double-chamber construction and integrated cooling, heating, humidification, filtration and sterilization.

CategoryHVAC
AvailabilityQuotation required
SupportOEM / ODM available
KEY FEATURES

One stop solution for HVAC and clean room

  • Designed in accordance with EN1886 mechanical performance standard
  • Bacteria-resistant, dust-resistant and easy to maintain
  • Closed double-chamber anti-cold-bridge design with patented double-S panel connection
  • High airflow and pressure; low air leakage and anti-condensation
  • Airflow 2,000–120,000 m³/h; maximum pressure 2,500 Pa
  • Cooling, dehumidification, heating, humidification, filtration, purification and sterilization
  • Comprehensive bacterial-control measures to prevent growth inside the unit
  • Suitable for operating rooms, pharmaceutical cleanrooms, laboratories and electronics

The cleanroom purification HVAC unit is designed for spaces where airborne particles and microbial contamination must be controlled. Its closed double-chamber construction, anti-cold-bridge design and hygienic surfaces support cleanroom classification and validation.

2,000–120,000 m³/hAirflow range
2,500 PaMax. pressure
EN1886Mechanical standard
HygienicBacterial control

Designed for contamination control

  • Closed double-chamber, anti-cold-bridge casing with patented double-S connection
  • Bacterial-resistant and dust-resistant internal surfaces
  • Cooling, dehumidification, heating, humidification, filtration and sterilization modules
  • Low air leakage and anti-condensation construction
  • High airflow and external static pressure for cleanroom duct systems

Applications

Hospital operating rooms, ICU and isolation rooms, pharmaceutical cleanrooms, laboratories, electronics and food production.

Cleanroom classification, filter grade and airflow balance are project-specific. FulCare can assist with the AHU schedule and cleanroom interface.

TECHNICAL SPECIFICATIONS

Models and specifications

StandardEN1886 mechanical performance
Airflow range2,000–120,000 m³/h
Max. pressure2,500 Pa
ConstructionClosed double-chamber anti-cold-bridge; double-S panel connection
HygieneBacterial-resistant, dust-resistant, easy to clean
FunctionsCooling, dehumidification, heating, humidification, filtration, purification, sterilization
Air leakageLow leakage design
ApplicationHospital operating rooms, pharmaceutical cleanrooms, laboratories, electronics, food
APPLICATIONS
Hospital operating rooms; ICU; pharmaceutical cleanrooms; laboratories; electronics; food